Liquid Chromogenic Culture Media
Liquid Chromogenic Culture Medium
 Coliforms and E. coli liquid chromogenic medium
 Performance Characteristics of Liquid Chromogenic Culture Media
1. It is included in the "Japan Food Hygiene Guide" (2004 edition) with strong authoritative influence.
 2. There are two kinds of chromogenic substances, which can directly recognize coliforms and E. coli.
 3. The test results can be obtained within 24 hours, but BGLB needs 48 hours.
 4. No need for a fermentation tube and a constant temperature pool with low cost and easy operation.
 5. No need to prepare medium and wash tubes (except XM powder medium).
 6. No need for identification and supplementation experiments such as EMB culture.
 7. E.coli O157 cannot be identified separately but qualitative testing only.
 Product Details of Liquid Chromogenic Culture Media
 Name
Model
Application
Capacity
Packing
Validity Period
Liquid chromogenic culture medium
XM-30
For 1ml sample inspection
10ml/cup
128 cups/carton
1 year
Liquid chromogenic culture medium
XM-31
For 10ml sample inspection
10ml/cup
128 cups/carton
Liquid chromogenic culture medium
XM-32
For 5ml sample inspection
5ml/cup
128 cups/carton
XM powder medium
XM0001
For preparing medium
8.5g/bag
20 bags/carton
3 years
MT opener
OS-01
For MT container opening
/
1pc
/
 Usage Method of Liquid Chromogenic Culture Media
1. Container surface sterilization: The surface of the aluminum foil should be disinfected with an alcohol lamp before use.
2. Opening: Open the aluminum foil with an MT opener (OS-01) or open directly with a sterile pipette.
3. Inject the sample diluent: use a pipette to inject the sample dilution into the cup
XM-30: 1ml, XM-31: 10ml, XM-32: 5ml
4. Cultivation: Culture time: 24 hours; Culture temperature: 36 ± 1 °C
5. Disposal: Dispose of them after sterilization
※XM powder medium usage: Dissolve 500ml of pure water per bag, inject 10ml into the test tube, autoclave, then inject 1ml sample, and incubate at 36±1°C for 24 hours. The identification method is the same.
 Coloring Principle
Coliforms positive
There is a special β-galactosidase only exit in the coliforms. It can be used as an indicator enzyme for coliform bacteria, which catalyzes the hydrolysis of the substrate X-GAL to form 5,5-dibromo -4,4-dichloro indigo, appearing light blue ~ purple-blue.
E. coli positive
β--glucuronidase can be used as an indicator enzyme for Escherichia coli; because β-glucuronidase can be observed in Escherichia coli, Salmonella and Shigella in intestinal bacteria, and 95% of E. coli contains β-glucuronidase. It catalyzes the hydrolysis of MUG to form 4-methylumbelliferon, which exhibits fluorescence at 366 nm ultraviolet light and is visually discernible under indoor light intensity.
 https://www.elexbio.com/liquid-chromogenic-culture-media.html
Tumblr media
0 notes
elexbio · 3 years
Text
Homogenizer
Performance Characteristics of Homogenizer
1. The exclusive design of the crushing plate adopts a hard rubber blade that has a strong crushing ability. The smashing takes a short time, which is about half of the conventional method.
 2. Stainless steel material is used. The sample has no contact with the laboratory homogenizer, and the packaging is hygienic and safe.
 3. The mobile glass door switch is easy to load and unload, and the smashing state of the sample can be directly observed through a transparent window.
 4. The instrument can be used with our dispensing pump to fully mix the diluted sample.
 5. There are manual mode and an automatic mode, and the smashing time can be easily set.
 Crushing Ability Comparison
 Conventional flat bats are difficult to completely smash the sample, and the new pulverized plate with a hard rubber blade can completely smash the sample in a short time.
 Functional application
 1. The instrument is suitable for sample preparation of microbial analysis of various foods, medicines, and cosmetics.
 2. Put the substance to be tested into the blender bag and inject the dilution solution (our company's dispensing pump is suitable for solvent diluent ), close the glass door, the pulverizing plate of the homogenizer will start to slap, the pressure generated will crush and mix the contents of the bag.
3. Specification of Homogenizer
4. Name
5. Model
6. Specification
7. Validity Period
8. Homogenizer
9. Pro•media SH-ⅡM
10. Power supply: AC110V
11. 1 year
12. Power: 100W
13. Weight: 17KGS
14. Dimension: 255*345*345mm
15. Automatic mode: 15s, 30s, 30s
16. Manual mode: automatic shutdown after 10 minutes of continuous operation
17. The matching use of the company's homogenized bag series is more effective.
 https://www.elexbio.com/homogenizer.html
Tumblr media
0 notes
elexbio · 3 years
Text
Dispensing Pump
Performance Characteristics of Dispensing Pump
1. Small size, light design, easy to clean and move.
 2. According to the operation needs, the nozzle can be installed freely left and right.
 3. The pneumatic type liquid feeding method is adopted, and the dispensing speed is increased by 20% compared with the original product.
 4. The dilution solution can use our company's sterilization diluents MV2-1000PBS or filling the homemade dilution solution into the matching sterilization bottle SB4000 to contact the device.
 5. Intelligent mode, automatic dilution: automatically measure the sample weight and multiple dilute the sample.
 There is no need to manually measure the sample weight.
 6. Quantitative dispensing: The packing amount can be set freely.
 7. Choose to have a printer and connect to a computer for data management.
 8. The specific dilution factor will be automatically archived for the next dilution.
 9. Stainless steel material is easy to clean. The pedal switch can be used in a clean stand.
 10. Low noise. It can be stopped quickly and no residual droplets.
Technical Specifications of Dispensing Pump
 Sample weight
0.5~1000g
Dilution amount
5~1000ml
Dilution precision
Within ±1.0g
Dilution speed
16.67ml/sec (6 seconds for 100ml dispensing)
Dilution multiple
2-999 times
Weighing range
0.1~1500g
Density setting
0.7-1.4g/ml
Material
Stainless steel
Power supply
AC 110V
Weight
7.5kg
Dimension
320х280х270mm
  Products Details of Dispensing Pump
Products List
Selective Purchasing products
Name
QTY
Name
Model
QTY
Warranty period
Dispensing pump
1 set
Printers (heat sensitive photocopiers, wiring, AC presses, heat sensitive paper)
PA030
1
1 year
Dispensing nozzle
1set
Computer Output Devices (Special Software, RS232C Wiring)
PA061
1
Silicone gel tube
2 pcs
Pedal switch
PA037
1
Electronic scale
1 set
4 liter sterilizing bottle, cap for injection/extraction, circular filter plate, silica gel tube (nozzle, infusion tube can be sterilized together after connecting)
SB4000
1 set
DT-Cube bracket(SUS)
1 set
MV2-1000 infusion apparatu
1 set
Sterilization diluents (phosphate buffered saline, 1 liter х10 bottles)
MV2-1000
1 set
For homogenizers, please refer to ELMEX's Pro•media SH-IIM.
It is better to use the company's diluents and homogenized blender bag series.
https://www.elexbio.com/dispensing-pump.html
Tumblr media
0 notes
elexbio · 3 years
Text
Diluents Series
In daily practical experiments, when the liquid samples are collected correctly, we often do not need a pure solution to carry out experiments. In order to get better and more accurate detection results, diluent water or other solutions will be added to obtain the solution with lower concentration. In this process, the solvent diluent is needed. In many laboratories, it is generally believed that direct preparation of buffer by diluent reagent will be more accurate and cheaper, which is not in line with the fact, because the quality of buffer is related to the purity of reagent, the accuracy of reagent weighing, the quality of purified water and other factors such as temperature, preparation container and so on.
   ELEX diluents series has greatly improved the trouble and inaccuracy caused by the preparation of diluents on site. The product mainly contains two types of diluents: gradient dilution and sterile diluents.
 Gradient dilution is the most widely used in the laboratory. It has phosphate-buffered saline, 1% buffered peptone water and 0.1% phosphate-buffered peptone saline. Other solutions can be customized according to customer needs. The wide push plate design of the front end of the gradient dilution liquid bottle cap minimizes the possibility of contact pollution when opening the cap; the tongue pressing design of the back end of the bottle cap facilitates the easy control of the opening angle of the cap by one hand, which make the operation more convenient, reasonable and convenient.
 Sterile diluents mainly have MT-11 series, MV2-90 series, MV-225 series (wide mouth), MV2-1000 series and MV-1000 series, equipped with PBS, BPW, MRD and AP solutions. MT-11 series contains 9ml diluents, which is similar to gradient diluents GD-9 for gradient dilution. Customers can customize different types of diluents according to their own needs. The series of buffers are prepared with high standard substances under purified environment and sterilized by irradiation. They are suitable for dilution of different quantities of samples. Some products can be used in conjunction with various devices produced by our company to prevent secondary pollution, which is safe, highly efficient and easy to operate.
 https://www.elexbio.com/diluents-series/
Tumblr media
0 notes
elexbio · 3 years
Text
Culture Media Series
In microbial detection, when the sample is collected and diluted correctly, the prepared sample solution needs to select the appropriate culture medium for cultivation, so as to judge whether the sample meets the standard. The choice of culture medium means whether we can get the desired experimental results quickly. ELEX is a culture media supplier providing culture medium that is mainly used for rapid detection, to make the microbial detection more simple and effective. The culture media of microbiology mainly include DNP Medi·Ca culture medium plate, concentrated liquid chromogenic medium, tri-color agar medium, and liquid chromogenic medium.
 Different types of culture media for bacterial growth have their own characteristics. ELEX Biological, one of the most professional culture media suppliers, can provide different types of culture media with high quality. Compared with other agar media, DNP media is a kind of culture media for food microbiology, which makes the food microbial detection much easier, more standardized, more efficient and pollution-free. It can be used directly after opening, easy to see colony, and can reduce the cultivation area and waste gas.  At present, AC test tablets are used to detect the total number of common colonies, CC test tablets to detect coliforms bacteria, EC test tablets to simultaneously detect E.coli and coliforms bacteria, SA test tablets to detect Staphylococcus aureus. All of ELMEX's Medi·Ca culture medium plate have passed the AOAC authoritative certification, and have been included in the Japanese food hygiene inspection guidelines.
 Compared with the traditional medium, DNP Film·Media Culture Medium Plate has the following advantages. Firstly, the preparation process of the medium is omitted which saves time; the steps are reduced which lower the possibility of contamination in the process. Secondly, the medium plate can be placed overlapping, saving about 95% of the cultivation space, in addition to reducing emissions of exhaust gas and greenhouse gas (GHG), which save s environmental protection costs. Thirdly, it is easy to operate and does not depend on the operator's level. The bacterial colony is easy to see with convenient judgment and accurate result.
 Compared with other similar products, it also has the following advantages: firstly, sample dropping can be carried out uniformly without pressure plate with fewer steps which is fast and convenient; secondly, there is a special anti-spillover ring, sample liquid will not spill and lead to cross-contamination.
 Concentrated liquid chromogenic medium ST-SSP can be used in combination with our swab simpler, and can be used for the qualitative detection of E. coli and coliforms at the same time.
 Tri-color agar medium is widely used for simultaneous qualitative and quantitative detection of coliform bacteria, Escherichia coli and other intestinal bacteria in food, water, milk, ice cream and meat products. Colonies show three colors, which can be easily judged and counted.
 There are two kinds of chromogenic substances in liquid chromogenic medium, which can directly identify coliforms and Escherichia coli, but only for qualitative detection.
https://www.elexbio.com/culture-media-series/
Tumblr media
0 notes
elexbio · 3 years
Text
Contact Agar Medium 4x4
Performance Characteristics of Contact Agar Medium 4x4
1. It is widely used in environmental sanitation, apparatus, sedimentation bacteria, and hand colony inspection.
 2. It can be used directly after opening, no need to prepare a medium which saves much time.
 3. The medium area is 10 cm². It's divided into 10 small cells which are easy to count.
 Microbiology Agar Medium Types
AC • Standard Plate Counting Agar Based Medium
 Used for the identification of the total bacteria number.
 EC • Three-color Agar Based Medium
 Escherichia coli and coliforms can be simultaneously detected.
 E.coli colonies are blue to light purple.
 Coliform colonies are red to purple.
 Other intestinal bacterial colonies were milky white.
 SA • Staphylococcus Aureus Agar Based Medium
 Staphylococcus aureus forms black colonies on the surface of the culture medium, and due to protein breakdown, a transparent hemolysis ring or turbid zone is formed around the Staphylococcus aureus colonies.
 PD • Yeast, Mold Agar Based Medium
 Used for the identification of yeast and mold.
Usage Method of Contact Agar Medium 4x4
1.  Remove the medium from the bag.
 2.  Open the lid and press the petri dish directly onto the sample to be sampled.
3. Cover the lid, mark it in the blank column of the container, and culture it in the incubator.
4. Colonies were counted after culture. Medium area: 10cm².
 Product Details of Contact Agar Medium 4x4
Name
Characteristics
Package
Culture time
Validity Time
Agar Stamp  AC
Total Bacteria Count Agar 10cm²
10pcs/bag; 100pcs/box
48±2 hours
6 months
Agar Stamp  EC
Coliform group&E.coli Count Agar 10cm²
24 hours
Agar Stamp  SA
Staphylococcus aureus Count Agar 10cm²
24~48 hours
Agar Stamp  PD
Yeast&Mold Count Agar 10cm²
5 days
Note: 1. The product should be protected from light and stored at room temperature.
2. It should be used as soon as possible after unpacking.
3. When there are water droplets in the container, please gently remove the water droplets and use.
https://www.elexbio.com/contact-agar-medium-4x4.html
Tumblr media
0 notes
elexbio · 3 years
Text
Contact Agar Medium 5x5
Performance Characteristics of Contact Agar Medium 5x5
1. It is widely used in environmental sanitation, apparatus, sedimentation bacteria and hand colony inspection.
 2. It can be used directly after opening, no need to prepare medium which saves time and effort.
 3. The medium area is 24 cm². It is divided into several small cells which are easy to count.
 Agar Medium Type
AC• Standard Plate Counting Agar Medium
 Used for the identification of the total bacteria number.
 EC•Three-color agar medium
 Escherichia coli and coliforms are simultaneously detected.
 E.coli colonies are blue to light purple.
 Coliform colonies are red to purple.
 Other intestinal bacterial colonies were milky white.
 SA•Staphylococcus aureus agar medium
 Staphylococcus aureus forms black colonies on the surface of the culture medium, and due to protein breakdown, a transparent hemolysis ring or turbid zone is formed around the Staphylococcus aureus colonies.
 PD•Yeast, mold agar medium
 For the identification of yeast and mold.
 Usage Method of Contact Agar Medium 5x5
1.  Remove the medium from the bag.
  Open the lid and press the petri dish directly onto the sample to be sampled.
 3.  Cover the lid, mark it in the blank column of the container, and culture it in the incubator.
4.  Colonies were counted after culture. Medium area: 24 cm².
 Product Details of Contact Agar Medium 5x5
Name
Characteristics
Package
Culture time
Validity Time
Agar Stamp  AC
Total Bacteria Count Agar, 10cm²
10pcs/bag; 100pcs/box
48±2 hours
6 months
Agar Stamp  EC
Coliform group&E.coli Count Agar, 10cm²
24 hours
Agar Stamp  SA
Staphylococcus aureus Count Agar, 10cm²
24~48 hours
Agar Stamp  PD
Yeast&Mold Count Agar, 10cm²
5 days
 Note: 1. The product should be protected from light and stored at room temperature.
2. It should be used as soon as possible after unpacking.
3. When there are water droplets in the container, please gently remove the water droplets and use.
 https://www.elexbio.com/contact-agar-medium.html
Tumblr media
0 notes
elexbio · 3 years
Text
Colony Counter
Smart iSac Simple Calculation 1. Simple Count Simultaneous calculation of 6 sheet medium; Correct the value of each medium; The result can be preserved as portrait data; The result cannot generate data documents; There are simultaneous counting functions of 6 sheet medium and a correction function for each medium value; Simply input an existing job.
Smart iSac Total Calculation 1. Simple count 2. OCR method Read 8 lines of numbers and automatically generates data documents. Automatically record bacterial numbers and image data The result can be output as a CSV file 8-line QR code for parallel use 3. Barcode method After the data is generated, the QR code can be used to generate the data document. Automatic recording of bacterial number and image data The result can be output as a CSV file
Equivalent media with other company Other company ELEX 3M TM culture media plate TM agar DNP Media·Ca culture media plate AC culture media plate for total bacteria number Media·Ca AC for total bacteria number RAC culture media plate for rapid measuring bacteria number / CC culture media plate for coliforms number Media·Ca CC for coliforms EC culture media plate for g E.coli and EC coliform Media·Ca EC for E.coli and coliforms STX culture media plate for S. aureus assay Media·Ca SA for Staphylococcus aureus
AQHC test piece for the identification of bacteria number in the water (subordinate vegetative bacteria)
Counting System Counting system simultaneous calculations of 6 sheet test piece Calculated value correction Data Preservation Original document Automatic document Colony conversion Qualified judgment CSV document Simple count ○ ○ ○※2 × × × × × OCR method ○ ○ ○ × ○ ○ ○ ○ Barcode method ○ ○ ○ ○ ○ ○ × ○ ※ 2 can be preserved as portrait data.
Specification of Automatic Bacterial Colony Counter Name Code No. Content Counting System Simple Count OCR method Barcode method Smart iSac  simple calculation C001-5S Laptop ○ × × Scanner Smart iSac  total calculation C001-5M Laptop ○ ○ ○ Scanner QR CODELEADER
Performance Characteristics of Automatic Bacterial Colony Counter 1. Rapid bacterial counting The processing capacity of simultaneous counting of 6 sheet culture media plate is about 6 times of the visual counting, which can further achieve the function of improving accuracy by the new technology; Culture media plate is used with DNP Media·Ca media, and 6 sheets can be read simultaneously by scanning. If the range and sensitivity of the count size need to modify, you can click on the above image and make the subtle adjustments by manual operation. Performance Characteristics 2. Data Preservation and Verification
Check data records, agar images, and calculated values, etc;
Preserve past data to reconfirm and compare;
The result can be output as a CSV file;
The result also can be converted to EXCEL and other files. 3. Massive Data Sharing
Set up a computer as server management or use a cloud server to achieve the headquarters' management of each factory.
https://www.elexbio.com/colony-counter.html
Tumblr media
0 notes
elexbio · 4 years
Text
Liquid Chromogenic Culture Media
Liquid Chromogenic Culture Medium
Coliforms and E. coli liquid chromogenic medium
Performance Characteristics of Liquid Chromogenic Culture Media
1. It is included in the "Japan Food Hygiene Guide" (2004 edition) with strong authoritative influence.
2. There are two kinds of chromogenic substances, which can directly recognize coliforms and E. coli.
 3. The test results can be obtained within 24 hours, but BGLB needs 48 hours.
4. No need for a fermentation tube and a constant temperature pool with low cost and easy operation.
5. No need to prepare medium and wash tubes (except XM powder medium).
6. No need for identification and supplementation experiments such as EMB culture.
7. E.coli O157 cannot be identified separately but qualitative testing only.
Product Details of Liquid Chromogenic Culture Media
Name
Model
Application
Capacity
Packing
Validity Period
Liquid chromogenic culture medium
XM-30
For 1ml sample inspection
10ml/cup
128 cups/carton
1 year
Liquid chromogenic culture medium
XM-31
For 10ml sample inspection
10ml/cup
128 cups/carton
Liquid chromogenic culture medium
XM-32
For 5ml sample inspection
5ml/cup
128 cups/carton
XM powder medium
XM0001
For preparing medium
8.5g/bag
20 bags/carton
3 years
MT opener
OS-01
For MT container opening
/
1pc
/
Usage Method of Liquid Chromogenic Culture Media
1. Container surface sterilization: The surface of the aluminum foil should be disinfected with an alcohol lamp before use.
2. Opening: Open the aluminum foil with an MT opener (OS-01) or open directly with a sterile pipette.
3. Inject the sample diluent: use a pipette to inject the sample dilution into the cup
XM-30: 1ml, XM-31: 10ml, XM-32: 5ml
4. Cultivation: Culture time: 24 hours; Culture temperature: 36 ± 1 °C
5. Disposal: Dispose of them after sterilization
※XM powder medium usage: Dissolve 500ml of pure water per bag, inject 10ml into the test tube, autoclave, then inject 1ml sample, and incubate at 36±1°C for 24 hours. The identification method is the same.
Coloring Principle
Coliforms positive
There is a special β-galactosidase only exit in the coliforms. It can be used as an indicator enzyme for coliform bacteria, which catalyzes the hydrolysis of the substrate X-GAL to form 5,5-dibromo -4,4-dichloro indigo, appearing light blue ~ purple-blue.
E. coli positive
β--glucuronidase can be used as an indicator enzyme for Escherichia coli; because β-glucuronidase can be observed in Escherichia coli, Salmonella and Shigella in intestinal bacteria, and 95% of E. coli contains β-glucuronidase. It catalyzes the hydrolysis of MUG to form 4-methylumbelliferon, which exhibits fluorescence at 366 nm ultraviolet light and is visually discernible under indoor light intensity.
https://www.elexbio.com/liquid-chromogenic-culture-media.html
Tumblr media
0 notes
elexbio · 4 years
Text
Homogenizer
Performance Characteristics of Homogenizer
1. The exclusive design of the crushing plate adopts a hard rubber blade that has a strong crushing ability. The smashing takes a short time, which is about half of the conventional method.
2. Stainless steel material is used. The sample has no contact with the laboratory homogenizer, and the packaging is hygienic and safe.
3. The mobile glass door switch is easy to load and unload, and the smashing state of the sample can be directly observed through a transparent window.
4. The instrument can be used with our dispensing pump to fully mix the diluted sample.
 5. There are manual mode and an automatic mode, and the smashing time can be easily set.
Crushing Ability Comparison
Conventional flat bats are difficult to completely smash the sample, and the new pulverized plate with a hard rubber blade can completely smash the sample in a short time.
Functional application
1. The instrument is suitable for sample preparation of microbial analysis of various foods, medicines, and cosmetics.
2. Put the substance to be tested into the blender bag and inject the dilution solution (our company's dispensing pump is suitable for solvent diluent ), close the glass door, the pulverizing plate of the homogenizer will start to slap, the pressure generated will crush and mix the contents of the bag.
Specification of Homogenizer
Name
Model
Specification
Validity Period
Homogenizer
Pro•media SH-ⅡM
Power supply: AC110V
1 year
Power: 100W
Weight: 17KGS
Dimension: 255*345*345mm
Automatic mode: 15s, 30s, 30s
Manual mode: automatic shutdown after 10 minutes of continuous operation
he matching use of the company's homogenized bag series is more effective.
 https://www.elexbio.com/homogenizer.html
Tumblr media
0 notes
elexbio · 4 years
Text
DNP Medi · Ca Culture Dish Media
Microbiology Test Piece Medi-Ca of DNP Medi·Ca Culture Dish Media
Make food microbiological testing much easier and more effective
Compared with the agar medium, our bacterial culture media plate makes the detection of food microorganisms easier, more standardized, and more efficient, but without pollution.
1. Culture media ready to be used after opening;
2. Colonies easy to see;
3. Reduce the culture area and waste.
Notes
1) The product is used for the microbiological examination of foods and beverages, and cannot be used clinically.
2) Do not open the tectorial membrane before transplanting the sample.
3) Do not use expired products.
4) Do not use products that are damaged, deformed, discolored, dirty, or foreign matters.
5) Do not expose the product to ultraviolet light or sunlight.
6) Do not press the film after the sample liquid is dropped. This will cause the sample solution to overflow to the outside of the culture area.
7) When the sample solution overflows from the culture area, replace it with a new one.
8) If the product enters the eye or mouth, immediately wash it with water and go to the hospital.
9) When using the product, it is susceptible to microbial contamination. Perform specific operations under the guidance of relevant qualified personnel.
10) Please note that the sample or the product that has been in contact with the sample liquid is a contaminated item.
Preservation method
Keep in cold storage (2~8°C), fold it twice at the opening of the bag after breaking, and fix it with tape.
Validity period
The validity period of the product is written on the aluminum bag and the upper part of the product (the date described after "EXP" is the validity period). Please use the aluminum bag within 3 months after opening.
 Abandonment method
The product has a risk of secondary pollution after use. Therefore, after proper sterilization, it should be disposed of according to the waste standards of the respective samples and related facilities.
Guarantee responsibility
When the product defect is obvious, replace the corresponding quantity with the new product. The judgment and application of the inspection results are the user’s responsibility, and the manufacturing company and the agent of the product are exempt from liability.
Quantity per carton
Medi-Ca AC and Medi-Ca CC: 1000 sheets
Medi-Ca EC and Medi-Ca SA: 500 sheets
Performance Characteristics of DNP Medi·Ca Culture Dish Media
Medium ready to be used after opening
The product does not require pre-modulation and autoclaving, just check it. No need for mixed release. Double layer coverage is easy to operate which will improve working efficiency.
Colonies easy to see
Due to the use of the color former, the colonies are clearly visible and easy to discriminate. It is beneficial to improve the working efficiency of counting bacteria and working standardization. In addition, since Medi-Ca AC is a bacillus, it is one of the characteristics that the coloring penetration is relatively small.
Reduce the culture area and waste
Compared with the culture dish, it can be reduced to about 1/15~1/20, which can reduce the storage space and the waste after use.
Variety introduction
The Culture Media Plate Medi-Ca is not considered for personal visual differences but produced according to the coloring universal design that most people can easily see, and is also certified by the NPO corporate coloring general design agency.
Usage Method of DNP Medi·Ca Culture Dish Media
1.  Sample liquid preparation
Add appropriate sterile dilutions to the sample and homogenize with a homogenizer.
2. Pipetting into the culture area
3.Culture
Put into the incubator, the product can overlap up to 25 pieces.
4.Judgment
SA uses chromogenic enzymes to easily determine and count bacteria.
When the bacteria number is large, please perform statistics in the grid on the film (1cm × 1cm).
 Multiply the bacteria number in a grid by the total grids number
5. Fishing for colonies which can be re-cultured
Remove the bacteria by opening the membrane.
Colony Count System
By using the colony counting system (dedicated scanner and application), high-resolution images can be analyzed, and automatic counting and inspection result image storage management can be realized in a short time, which can improve the counting efficiency.
Tear off the foil pouch and remove the required amount.
Medium Type
Culture temperature
Culture time
Media-Ca AC (Measurement of general bacteria amount)
35 ± 1 ℃
48±2 hours
Media-Ca CC (Measurement of Coliforms)
35 ± 1 ℃
24±1 hours
Media-Ca EC (Measurement of Escherichia coli and Coliforms)
35 ± 1 ℃
24±1 hours
Media-Ca SA (Measurement of Staphylococcus)
35 ± 1 ℃
24±1 hours
https://www.elexbio.com/dnp-medica-culture-dish-media.html
Tumblr media
0 notes
elexbio · 4 years
Text
Dispensing Pump
Performance Characteristics of Dispensing Pump
1. Small size, light design, easy to clean and move.
2. According to the operation needs, the nozzle can be installed freely left and right.
3. The pneumatic type liquid feeding method is adopted, and the dispensing speed is increased by 20% compared with the original product.
 4. The dilution solution can use our company's sterilization diluents MV2-1000PBS or filling the homemade dilution solution into the matching sterilization bottle SB4000 to contact the device.
5. Intelligent mode, automatic dilution: automatically measure the sample weight and multiple dilute the sample.
There is no need to manually measure the sample weight.
6. Quantitative dispensing: The packing amount can be set freely.
7. Choose to have a printer and connect to a computer for data management.
8. The specific dilution factor will be automatically archived for the next dilution.
9. Stainless steel material is easy to clean. The pedal switch can be used in a clean stand.
10. Low noise. It can be stopped quickly and no residual droplets.
Technical Specifications of Dispensing Pump
Sample weight
0.5~1000g
Dilution amount
5~1000ml
Dilution precision
Within ±1.0g
Dilution speed
16.67ml/sec (6 seconds for 100ml dispensing)
Dilution multiple
2-999 times
Weighing range
0.1~1500g
Density setting
0.7-1.4g/ml
Material
Stainless steel
Power supply
AC 110V
Weight
7.5kg
Dimension
320х280х270mm
 Products Details of Dispensing Pump
Products List
Selective Purchasing products
Name
QTY
Name
Model
QTY
Warranty period
Dispensing pump
1 set
Printers (heat sensitive photocopiers, wiring, AC presses, heat sensitive paper)
PA030
1
1 year
Dispensing nozzle
1set
Computer Output Devices (Special Software, RS232C Wiring)
PA061
1
Silicone gel tube
2 pcs
Pedal switch
PA037
1
Electronic scale
1 set
4 liter sterilizing bottle, cap for injection/extraction, circular filter plate, silica gel tube (nozzle, infusion tube can be sterilized together after connecting)
SB4000
1 set
DT-Cube bracket(SUS)
1 set
MV2-1000 infusion apparatus
1 set
Sterilization diluents (phosphate buffered saline, 1 liter х10 bottles)
MV2-1000
1 set
For homogenizers, please refer to ELMEX's Pro•media SH-IIM.
It is better to use the company's diluents and homogenized blender bag series.
https://www.elexbio.com/dispensing-pump.html
Tumblr media
0 notes
elexbio · 4 years
Text
Diluents Series
In daily practical experiments, when the liquid samples are collected correctly, we often do not need a pure solution to carry out experiments. In order to get better and more accurate detection results, diluent water or other solutions will be added to obtain the solution with lower concentration. In this process, diluents are needed. In many laboratories, it is generally believed that direct preparation of buffer by reagent will be more accurate and cheaper, which is not in line with the fact, because the quality of buffer is related to the purity of reagent, the accuracy of reagent weighing, the quality of purified water and other factors such as temperature, preparation container and so on.
ELEX diluents series has greatly improved the trouble and inaccuracy caused by the preparation of diluents on site. The product mainly contains gradient dilution and sterile diluents.
Diluents Series
In daily practical experiments, when the liquid samples are collected correctly, we often do not need a pure solution to carry out experiments. In order to get better and more accurate detection results, diluent water or other solutions will be added to obtain the solution with lower concentration. In this process, diluents are needed. In many laboratories, it is generally believed that direct preparation of buffer by reagent will be more accurate and cheaper, which is not in line with the fact, because the quality of buffer is related to the purity of reagent, the accuracy of reagent weighing, the quality of purified water and other factors such as temperature, preparation container and so on.
ELEX diluents series has greatly improved the trouble and inaccuracy caused by the preparation of diluents on site. The product mainly contains gradient dilution and sterile diluents.
Phosphate Buffered Saline
Phosphate Buffered Saline
Gradient Diluents GD-9 Series of Gradient Dilution is the most widely used in the laboratory.
Sterile Diluents
After irradiation sterilization, it is suitable for the dilution of different samples. Some products can be used with various devices, which are simple, safe and easy to operate.
Gradient dilution is the most widely used in the laboratory. It has phosphate-buffered saline, 1% buffered peptone water and 0.1% phosphate-buffered peptone saline. Other solutions can be customized according to customer needs. The wide push plate design of the front end of the gradient dilution liquid bottle cap minimizes the possibility of contact pollution when opening the cap; the tongue pressing design of the back end of the bottle cap facilitates the easy control of the opening angle of the cap by one hand, which make the operation more convenient, reasonable and convenient.
Sterile diluents mainly have MT-11 series, MV2-90 series, MV-225 series (wide mouth), MV2-1000 series and MV-1000 series, equipped with PBS, BPW, MRD and AP solutions. MT-11 series contains 9ml diluents, which is similar to gradient diluents GD-9 for gradient dilution. Customers can customize different types of diluents according to their own needs. The series of buffers are prepared with high standard substances under purified environment and sterilized by irradiation. They are suitable for dilution of different quantities of samples. Some products can be used in conjunction with various devices produced by our company to prevent secondary pollution, which is safe, highly efficient and easy to operate.
 https://www.elexbio.com/diluents-series/
Tumblr media
0 notes
elexbio · 4 years
Text
Culture Media Series
In microbial detection, when the sample is collected and diluted correctly, the prepared sample solution needs to select the appropriate culture medium for cultivation, so as to judge whether the sample meets the standard. The choice of culture medium means whether we can get the desired experimental results quickly. ELEX is a culture media supplier providing culture medium that is mainly used for rapid detection, to make the microbial detection more simple and effective. The products mainly include DNP Medi·Ca culture medium plate, concentrated liquid chromogenic medium, tri-color agar medium, and liquid chromogenic medium.
Different types of culture media for bacterial growth have their own characteristics. Compared with other agar media, DNP media can make the food microbial detection much easier, more standardized, more efficient and pollution-free. It can be used directly after opening, easy to see colony, and can reduce the cultivation area and waste gas. At present, AC test tablets are used to detect the total number of common colonies, CC test tablets to detect coliforms bacteria, EC test tablets to simultaneously detect E.coli and coliforms bacteria, SA test tablets to detect Staphylococcus aureus. All of ELMEX’s Medi·Ca culture medium plate have passed the AOAC authoritative certification, and have been included in the Japanese food hygiene inspection guidelines.
Compared with the traditional medium, Medi·Ca culture medium plate has the following advantages. Firstly, the preparation process of the medium is omitted which saves time; the steps are reduced which lower the possibility of contamination in the process. Secondly, the medium plate can be placed overlapping, saving about 95% of the cultivation space, in addition to reducing emissions of exhaust gas and greenhouse gas (GHG), which save s environmental protection costs. Thirdly, it is easy to operate and does not depend on the operator's level. The bacterial colony is easy to see with convenient judgment and accurate result.
Compared with other similar products, it also has the following advantages: firstly, sample dropping can be carried out uniformly without pressure plate with fewer steps which is fast and convenient; secondly, there is a special anti-spillover ring, sample liquid will not spill and lead to cross-contamination.
Concentrated liquid chromogenic medium ST-SSP can be used in combination with our swab simpler, and can be used for the qualitative detection of E. coli and coliforms at the same time.
Tri-color agar medium is widely used for simultaneous qualitative and quantitative detection of coliform bacteria, Escherichia coli and other intestinal bacteria in food, water, milk, ice cream and meat products. Colonies show three colors, which can be easily judged and counted.
There are two kinds of chromogenic substances in liquid chromogenic medium, which can directly identify coliforms and Escherichia coli, but only for qualitative detection.
 https://www.elexbio.com/culture-media-series/
Tumblr media
0 notes
elexbio · 4 years
Text
Contact Agar Medium 4x4
Performance Characteristics of Contact Agar Medium 4x4
1. It is widely used in environmental sanitation, apparatus, sedimentation bacteria, and hand colony inspection.
 2. It can be used directly after opening, no need to prepare a medium which saves much time.
 3. The medium area is 10 cm². It's divided into 10 small cells which are easy to count.
Microbiology Agar Medium Types
AC • Standard Plate Counting Agar Based Medium
Used for the identification of the total bacteria number.
Contact Agar Medium 4x4
Contact Agar Medium 4x4  PDF Download  Get A Quote
Performance Characteristics of Contact Agar Medium 4x4
1. It is widely used in environmental sanitation, apparatus, sedimentation bacteria, and hand colony inspection.
2. It can be used directly after opening, no need to prepare a medium which saves much time.
3. The medium area is 10 cm². It's divided into 10 small cells which are easy to count.
Microbiology Agar Medium Types
AC • Standard Plate Counting Agar Based Medium
Used for the identification of the total bacteria number.
ELEX Press sampling-AC
EC • Three-color Agar Based Medium
Escherichia coli and coliforms can be simultaneously detected.
E.coli colonies are blue to light purple.
Coliform colonies are red to purple.
Other intestinal bacterial colonies were milky white.
SA • Staphylococcus Aureus Agar Based Medium
Staphylococcus aureus forms black colonies on the surface of the culture medium, and due to protein breakdown, a transparent hemolysis ring or turbid zone is formed around the Staphylococcus aureus colonies.
PD • Yeast, Mold Agar Based Medium
Used for the identification of yeast and mold.
Usage Method of Contact Agar Medium 4x4
1.  Remove the medium from the bag.
2. Open the lid and press the petri dish directly onto the sample to be sampled.
3. Cover the lid, mark it in the blank column of the container, and culture it in the incubator.
4. Colonies were counted after culture. Medium area: 10cm².
 Product Details of Contact Agar Medium 4x4
Name
Characteristics
Package
Culture time
Validity Time
AC Stamp Order
Total Bacteria Count Agar 10cm²
10pcs/bag; 100pcs/box
48±2 hours
6 months
EC Stamp Order
Coliform group&E.coli Count Agar 10cm²
24 hours
In order to Stamp SA
Staphylococcus aureus Count Agar 10cm²
24~48 hours
PD Stamp Order
Yeast&Mold Count Agar 10cm²
5 days
Note: 1. The product should be protected from light and stored at room temperature.
 2. It should be used as soon as possible after unpacking.
 3.When there are water droplets in the container, please gently remove the water droplets and use.
https://www.elexbio.com/contact-agar-medium-4x4.html
Tumblr media
0 notes
elexbio · 4 years
Text
Contact Agar Medium 5x5
Performance Characteristics of Contact Agar Medium 5x5
1. It is widely used in environmental sanitation, apparatus, sedimentation bacteria and hand colony inspection.
2. It can be used directly after opening, no need to prepare medium which saves time and effort.
3. The medium area is 24 cm². It is divided into several small cells which are easy to count.
Agar Medium Type
AC• Standard Plate Counting Agar Medium
Used for the identification of the total bacteria number.
EC•Three-color agar medium
Escherichia coli and coliforms are simultaneously detected.
E.coli colonies are blue to light purple.
Coliform colonies are red to purple.
Other intestinal bacterial colonies were milky white.
SA • Staphylococcus aureus agar medium
Staphylococcus aureus forms black colonies on the surface of the culture medium, and due to protein breakdown, a       transparent hemolysis ring or turbid zone is formed around the Staphylococcus aureus colonies.
PD•Yeast, mold agar medium
For the identification of yeast and mold.
Usage Method of Contact Agar Medium 5x5
1.  Remove the medium from the bag.
2.  Open the lid and press the petri dish directly onto the sample to be sampled.
3.  Cover the lid, mark it in the blank column of the container, and culture it in the incubator.
4. Colonies were counted after culture. Medium area: 24 cm².
Product Details of Contact Agar Medium 5x5
Name
Characteristics
Package
Culture time
Validity Time
AC Stamp Order
Total Bacteria Count Agar, 10cm²
10pcs/bag; 100pcs/box
48±2 hours
6 months
EC Stamp Order
Coliform group&E.coli Count Agar, 10cm²
24 hours
In order to Stamp SA
Staphylococcus aureus Count Agar, 10cm²
24~48 hours
PD Stamp Order
Yeast&Mold Count Agar, 10cm²
5 days
 Note: 1. The product should be protected from light and stored at room temperature.
 2. It should be used as soon as possible after unpacking.
 3. When there are water droplets in the container, please gently remove the water droplets and use.
https://www.elexbio.com/contact-agar-medium.html
Tumblr media
0 notes
elexbio · 4 years
Text
Concentrated Liquid Chromogenic Culture Medium ST-SSP
The sample solution in ST-25 is discarded by the remaining 5 ml, and then 1.65 ml of the concentrated liquid chromogenic culture medium (ST-SSP) is completely injected to ST-25 for culture.
Performance Characteristics of Concentrated  Liquid Chromogenic Culture Media ST-SSP
ST-SSP can simultaneously detect coliforms and Escherichia coli for qualitative identification.
Name
Description
Packing
Validity period
ST-SSP
Coliforms and Escherichia coli for qualitative identification
10pcs/bag, 300pcs/box
1 year
 https://www.elexbio.com/concentrated-liquid-chromogenic-culture-media.html